Can it be measured? Forty-five minutes is enough to find out.Talk to us about your processLanguageENFR

What we can measure in your process

The question is almost never “can this technology measure that”. It is “at which step of your process does that measurement change a decision”.

PAT-INDUSTRY designs and deploys non-destructive in-line measurement. The measurement consumes no product: everything manufactured stays saleable. The table below reads by industry: for each unit operation, what is commonly measured there, and the page that details the technologies, the conditions for success and the limits.

Pharma

Unit operationWhat is measured there
Material receiptIdentity and conformity — see
BlendingBlend homogeneity — see
GranulationParticle size and water content — see
DryingWater content, and end of operation — see
CompressionDose uniformity — see
CoatingCoating thickness and uniformity — see
Solubilisation and dissolutionActive and excipient concentration — see
Emulsification and homogenisationDroplet size — see — and homogeneity — see
Viscous formulationViscosity, during the operation — see
Final controlInternal structure, through the pack — see — and identity — see

Drug substance

Unit operationWhat is measured there
ReactionProgress and stopping point — see
Crystallisation and polymorphismCrystal size — see — and polymorphism — see
Filtration and washingFiltrate composition — see
DryingWater and residual solvents — see
MillingParticle size distribution — see

Biopharma and biotech

Unit operationWhat is measured there
Cell cultureGlucose, lactate, density — see
PurificationComposition and identity — see
FormulationComposition and viscosity — see
LyophilisationResidual water content — see
Medium preparationComponent identity and titre after reconstitution — see
Dispersed forms(Nano)particle size and aggregation — see
FillingIdentity through the vial, by NIR and RAMAN — see

Chemicals and polymers

Unit operationWhat is measured there
ReactionProgress, by-products — see
Liquid formulationComposition — see
DryingWater content — see
DispersionPhase distribution — see
Crystallisation and wet millingSize distribution — see
Identity checking and sortingPolymer type, fillers and additives — see
PackingIn-line viscosity — see

Cosmetics

Unit operationWhat is measured there
Weighing and receiptMaterial identity — see
EmulsificationDroplet size — see — and phase distribution — see
BlendingHomogeneity and composition — see
Drying and powdersWater in a powder, a stick, an extract — see
PackingViscosity — see

Agriculture and food

Unit operationWhat is measured there
ReceiptIdentity, water content, protein — see
DryingWater content, and end of operation — see
BlendingHomogeneity — see
Fermentation and digestionMedium composition — see
Flow in a vessel or a pipePhase distribution, and the product changeover front on a shared line — see
Finished product controlComposition and colour, in the visible and near infrared — see — counting and morphology — see

Anaerobic digestion

Unit operationWhat is measured there
Feedstock reception and characterisationDry matter, organic matter, methane potential — see
Silage taken from the working faceDry matter, from one day to the next — see
Running the digesterFOS/TAC, volatile fatty acids, ammonium — see
Digestate on the way outDry matter, organic matter, nitrogen — see
Biomass dryingWater content, and end of operation — see

This table does not close the list

The operations and attributes above are the ones most often instrumented. They do not bound what can be measured. Part of our work is developing a measurement where none existed: an unusual matrix, an attribute nobody had tied to a physical quantity, a mechanical access thought impossible.

If your need is not in the table, it is not excluded from it: it has simply not been filed yet.

Two questions to ask before choosing a technology

Are you measuring a quantity or a state? A content, a concentration, a thickness are quantities: they need a model, therefore a campaign of reference samples and upkeep over time. A state — stabilised, homogeneous, conforming — is often obtained without a model. The two do not cost the same.

What mass of product does the measurement cover? A probe only sees the volume it illuminates. Depending on the technology that ranges from a few milligrams to several hundred grams, and it decides representativeness long before instrument performance does. What a sensor really sees.

Describe the operation, not the instrument

Forty-five minutes are enough to say whether a non-destructive measurement answers your question, and which one deserves a trial. Tell us your constraints too: the equipment already qualified, the classified area, the reference method you inherit, the pace at which the decision has to be made. Feasibility is often decided there rather than in the choice of technology.

Talk to us about your process